You have no items in your shopping cart.
Genuine Konica Minolta Fusing Unit Drive Assembly for machines listed on this page.
Symptoms: Squeaky noise or misfeeding.
Cause: Both symptoms are caused by faulty clutches CL5 p/n: A161M20400 and CL8 p/n: A161M20100
Solution: Replace the whole assembly (recommended) or replace both clutches and rebuild assembly.
CL5 clutch constantly drives a fuser section, even when machine is at stand by mode, while CL8 drives a transfer belt section, but only during copier operation.